| Sign In | Join Free | My bjjsgy.com | 
              
  | 
      
Brand Name : kimoems or OEM
Model Number : Refer to parameters
Certification : CE
Place of Origin : China
MOQ : 20pcs
Payment Terms : T/T
Output power factor : 1
Efficiency : 95.5%
Rated Voltage : 208/220/230/240Vac
Voltage Range : 110~300Vac
Rated Power : 6kVA/5400W/6000W
Frequency : 50/60±6Hz(default),±10Hz( Adjustable )
1/1 High Frequency UPS POWER SUPPLY Single Input Single Output 1kva To 10kva
True double-conversion online UPS POWER SUPPLY
●True double-conversion online UPS
●Output power factor 1.0
●User-friendly and easy-shift LCD display
●ECO and advanced ECO mode for energy saving
●Emergency Power Off Function (EPO)
●Efficiency 95.5%
●Charging Current Max 12Amp
●DSP technology applied
●Active input power factor correction 0.99
parameters
| 
 Model  | 
 6KVA  | 
 10KVA  | 
||||
| 
 Rated Power  | 
 6kVA/5400W/6000W  | 
 10kVA/9000W/10000W  | 
||||
| 
 Input  | 
 Wiring  | 
 L+N+PE  | 
||||
| 
 Rated Voltage  | 
 208/220/230/240VAC  | 
|||||
| 
 Voltage Range  | 
 110~300VAC 176~276VAC±5V@100%Load 110~176VAC@100%~50% Linear Load Derated :110VAC/300VAC@50%Load  | 
|||||
| 
 Frequency  | 
 50/60±6Hz(default),±10Hz( Adjustable )  | 
|||||
| 
 Power Factor  | 
 ≥0.99  | 
|||||
| 
 Generator  | 
 Compatibility  | 
|||||
| 
 Output  | 
 Wiring  | 
 L+N+PE  | 
||||
| 
 Rated Voltage  | 
 208/220/230/240Vac,Factory Preset:220Vac  | 
|||||
| 
 Output Voltage Regulation  | 
 ±1%  | 
|||||
| 
 Frequency  | 
 Online Mode: Follow Grid Frequency;Battery Mode:50/60±0.1Hz  | 
|||||
| 
 THD  | 
 Linear Load≤2%,Non-Linear Load≤5%(PF=0.8)  | 
|||||
| 
 Power Factor  | 
 0.9/1.0(Optional )  | 
|||||
| 
 Switching Time  | 
 0ms  | 
|||||
| 
 Overload  | 
 AC Mode:1102%~110% 30mins then transfer to bypass, 110%~130% 10mins & transfer to bypass, 130%~150% 30s, ≥150% 200ms transfer to bypass, Load≤70% recover to inverter mode.  | 
 Battery Mode:102%~109% 1minute backup then shutdown, 110%~130% 10s then shutdown,130%~150% 3s , ≥150% 200ms,(under BAT mode UPS will be closed after 1mins when INV. Turn off)  | 
||||
| 
 Crest Ratio  | 
 3:1  | 
|||||
| 
 Efficiency  | 
 Online Mode  | 
 95.5%@220Vac  | 
||||
| 
 Battery Mode  | 
 95.3%  | 
|||||
| 
 Battery and Charger  | 
 Battery Type  | 
 Lead Acid Maintenance Free Battery/ Lithium battery  | 
||||
| 
 Standard Model  | 
 12PCS(12~20adjustable)  | 
 16PCS(16~20adjustable)  | 
||||
| 
 Long-run Model  | 
 14/15/16/17/18/19/20(adjustable)  | 
 16/17/18/19/20(adjustable)  | 
||||
| 
 Battery over Voltage  | 
 N*13.65Vdc(1±1%)  | 
|||||
| 
 Battery under voltage  | 
 10V*N@Load>50%  | 
|||||
| 
 Shutdown Protection  | 
 Available  | 
|||||
| 
 Over-charging Protection  | 
 Available  | 
|||||
| 
 Charging Form  | 
 2 Stages/ 3 Stages Charging  | 
|||||
| 
 BAT Abnormal Alarm  | 
 Available  | 
|||||
| 
 Charging Current  | 
 1-12A Adjustable  | 
|||||
| 
 Communication  | 
 Port  | 
 RS232( Optional SNMP,USB,EPO)  | 
||||
| 
 Environmen  | 
 Ambient temperature  | 
 0~40℃  | 
||||
| 
 Humidity  | 
 20%~95% (No condensing)  | 
|||||
| 
 Storage temperature  | 
 -15~60℃ (Battery:0~40℃)  | 
|||||
| 
 Altitude  | 
 The altitude should not exceed 1000m, and the height above 1000m should be reduced to a maximum of 4000m. Refer to IEC62040  | 
|||||
| 
 Noise (dB)  | 
 ≤50db  | 
|||||
| 
 Tower  | 
 D×W×H(mm)  | 
 398*190*319mm  | 
 398*190*693mm  | 
 398*190*319mm  | 
 398*190*693mm  | 
|
| 
 Net Weight(kgs)  | 
 8.7 kg  | 
 43.4kg  | 
 9.7 kg  | 
 53kg  | 
||
| 
 Rack  | 
 D×W×H(mm)  | 
 UPS:380*438*88[2U]; Battery BOX:500*438*132[3U]  | 
||||
| 
 Net Weight(kgs)  | 
 8.3kg  | 
 52.1 kg  | 
 9.6kg  | 
 53.4kg  | 
||
| 
 Certification  | 
 EN/IEC 61000, EN/IEC 62040, GB/T 7260, GB/T 4943, YD/T1095, TLC  | 
|||||
| 
                                             | 
                
                        High Frequency Online UPS Tower Type Single Input Single Output 6kva To 10kva Images |